Sinnowa D320 Biochemistry Auto Analyzer (420 Tests/Hour)
Photometric: 320 Tests/Hour. ISE: 100 Tests/Hour
SINNOWA D320 Basic Technical Specifications
• Discrete constant speed 420 T/H
• Random Access (Emergency test input mode), Easy mode (Continuous loading mode),
Group loading.
• Automated HIS/LIS application (Data accept&send from/to hospital automation
system automatically)
• Test Methods: Kinetic, Endpoint, Differential(Sample Blank), Fixed Time, Protein
immunoassay,
Turbidimetric, Multicalibrators tests (1-6 Calibrator)
• 8-14 Different filters between 340nm-800nm give up compatibility all kind of tests
• External&Internal barcode reader for sample and reagents
• Low distillated water consumption(2-5 Liter/hour)
• 2 Probes(Sample-ISE, R1- R2 Probes) and Mixing Probe (1 Probe)
1. Refrigerated Reagent Compartments
- Real workstation consolidation with up to 40 different analytes in reagent pan (40 positions for for reagent1 and 40 positions for reagent2)
- Ready to use liquid stable reagents, mainly monoreagents.
- Liquid detection and remaining test number calculation
- Wide test ranges (See test menu)
- Stable cooling system by peltier element.
- Cover for protecting reagents from evaporation
- Continuous cooling at switching of analyzer main unit (Lamp saving system)
- Optional ready onboard SINNOWA reagent bottles
- Advanced automated/manual/selective/calibration and reagent quality control
2. Washing Station
- High tech wash station to ensure a valid diagnostics (8 times washing each reaction cuvets)
- Dirtiness control (Auto.blank control after washing react. cuvets)
- Vacuum draining liquid and 37°C preheated distillated water cleaning system
yielding to quick easy/drying system of reaction cuvettes system. (Patented Technology)
- Reaction cuvettes cleaning (washing) system with preheated distillated water
based on chemical cleaning function effect of 37°C heated distillated water. (Patented Technology)
- Eight fold water cleaning followed by a separate drying step to gain optimum system performance
3. Mixing Probe (Stirrer)
- Automated cleaning probe tips after each cleaning process
- High precision mixer stations to ensure excellent reaction conditions (Two mixing probes)
- Standardized mixing proced. across the whole range of analysis
- Different mixer positions for individual reaction steps (After reagent 1 and after reagent 2)
4. Reaction cuvettes wheel
- 90 reaction cuvets
- Non disposable plastic /quartz cuvettes (Reusable cuvettes)i
- Software driven carry over elimination
- Flexibility of total reaction volume between 180 µl-300 µl
- Autocontrolled by peltier element and optimized reaction temperature at 37°C , accurate ± 0,1 °C variation
- Rear sprectrophotometry of concave flat field grating fiber optic cable technology that provides low reaction detection at the same time on 14 different wavelengths.
- Cover for protecting reactions from evaporation, contamination and external light effects
- Photometric test accuracy:%1 Between 0.0000 OD(Abs.) to 5.0000 OD (Abs.)
- Carry Over Value :( Influencing one test from another) Less than %1
5. ISE Unit
- Integrated ISE unit.
- High quality ISE electrodes for Na, K, Cl,(or Li), PH and Ca.
- 12 months shelf life for all electrodes
- 100 tests/hour (If ISE mode only)
6. Sample Probe
- Sample volume as small as 2,0 µl as high as 100 µl
- Stable probe sensing system with liquid level detection, low sample alarm with voice/warning messages
- Probe save system (Collision protection- Crash prevention )
- Clot detection system (Clog detection system)
- Sample rerun and auto dilution (predilution or post dilution function)
- Primary(Vacuum blood tube), secondary tube(cuvet) compatibility
7. Sample Pan(Table)
- Positive sample identification to eliminate any sample mix ups
- Barcode reading technology to define different sample materials or other sample specifics
- 60 samples on board at the time for long walk away (All locations are ready to use for control, calibrator, urgent-random access tests)
8. Reagent Probe
- Stable probe sensing system with liquid level detection
- Probe save system (Collision protection- Crash prevention )
- Reagent volume as small as 10 µl-300 µl
- Calculation of remaining tests/vial, alarm after critical preprogrammed test number4
- Low reagent alarm with voice/warning messages
9. Windows based/integrated management program
- Compatible with windows 2000, XP, Vista
- User friendly interface
- Multitasking, flexible management program
- Automated maintenance (Combined many tasks at start up)
- Easy able to translate local language (Ready English,French, Turkish, Chinese, Arabic, Persian, Italian versions)
- Online status of reaction, reagent and sample plates
- Online monitoring Absorbance-time plot
- Profile inputting, calculated items
- Ready application inserts for SINNOWA Biochemistry&Turbidimetry Reagents, open reagent application system
- Online control system from central technic service (Remote Control)
- Unlimited users&profiles, more than 300 different tests program location
- Levey-jennings QC Charts, QC programs, QC results printing, statistical data extraction
10. Size and power requirements
- Size (cm):65-80-70 Weight:120 Kg
- Power: 220 Volt/50 Hz..
SINNOWA D320 BIOCHEMISTRY AUTO ANALYZER TEST MENU
Substrats Albumin Bicarbonate Bilirubin total Bilirubin direct Calcium Calcium Arsenazo Cholesterol Creatinine Glucose HDL-Cholesterol Iron Lactate LDL-Cholesterol Magnesium Phosphate Phospholipide Total Protein Triglycerides Urinary Protein UIBC Urea Uric Acid
Specific Proteins alpha-1-Antitrypsin alpha-1-Glycoprotein ß-2-Microglobulin Ceruloplasmin Haptoglobin Microalbumin Myoglobin Prealbumin D-Dimer
|
Enzyms ACP ALP alpha-Amylase CHE CK CK-MB GGT GOT (AST) GPT (ALT) HBDH LDH
DAU Amphetamine Barbiturates Benzodiazepines Cocaine EDDP Methadone Opiates THC
|
ISE Chloride Potassium Sodium
Calcium ionized and total
PH
Lithium
Homogeneous Immuno Assays Apo A1 Apo B ASL C3 C4 CRP IgA IgG IgM Ferritin HbA1c RF Transferrin
TDM Carbamazepine Digitoxin Digoxin Gentamicin Phenytoin Phenobarbital Theophylline Valproic Acid
|
SINNOWA reserves the right to change technical specification without prior notice.